EasyManua.ls Logo

Siemens SINAMICS G120D - r1725 Isd controller integral component limit; Isd_ctrl I_limit; p1726[0...n] Quadrature arm decoupling scaling; Transv_decpl scal; p1727[0...n] Quadrature arm decoupling at voltage limit scaling; TrnsvDecplVmaxScal; r1728 De-coupling voltage in-line axis; U_dir­axis_decoupl

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-221
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the limit value for the integral component of the Isd current controller.
Description: Sets the scaling of the quadrature arm decoupling
Note: This parameter is ineffective for sensorless vector control. In this case, p1727 is always used. If p1726 is set to 0,
then the quadrature de-coupling is de-activated. The integral component of the Isd current controller remains effec-
tive in the complete speed control range.
For the closed-loop control of synchronous motors, this parameter is used to scale the current controller de-cou-
pling.
Description: Sets the scaling of quadrature arm decoupling when the voltage limit is reached.
Description: Displays the actual output of the quadrature channel de-coupling for the d axis.
Description: Displays the actual output of the quadrature channel de-coupling for the q axis.
r1725 Isd controller integral component limit / Isd_ctrl I_limit
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2001 Dyn. index: -
Units group: 5_1 Unit selection: p0505 Func. diagram: 6714
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
p1726[0...n] Quadrature arm decoupling scaling / Transv_decpl scal
Access level: 4 Calculated: p0340 = 1 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6714
Min Max Factory setting
0.0 [%] 200.0 [%] 75.0 [%]
p1727[0...n] Quadrature arm decoupling at voltage limit scaling / TrnsvDecplVmaxScal
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6714
Min Max Factory setting
0.0 [%] 200.0 [%] 50.0 [%]
r1728 De-coupling voltage in-line axis / U_dir-axis_decoupl
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2001 Dyn. index: -
Units group: 5_1 Unit selection: p0505 Func. diagram: -
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r1729 De-coupling voltage quadrature axis / U_quad_decoupl
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2001 Dyn. index: -
Units group: 5_1 Unit selection: p0505 Func. diagram: -
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]