EasyManua.ls Logo

Siemens SINAMICS G120D - r20115 CO: MUL 1 product Y; MUL 1 product Y; p20116 MUL 1 run-time group; MUL 1 RTG; p20117 MUL 1 run sequence; MUL 1 RunSeq; p20118[0...1] CI: DIV 0 inputs; DIV 0 inputs

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-485
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Display parameter for the product Y = X0 * X1 * X2 * X3 of instance MUL 1 of the multiplier.
Description: Setting parameter for the run-time group in which instance MUL 1 of the multiplier is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance MUL 1 within the run-time group set in p20116.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of dividend X1 and divisor X2 of instance DIV 0 of the divider.
Index: [0] = Dividend X0
[1] = Divisor X1
Description: Display parameter for quotients Y = X1/X2, integer number quotients YIN, and division remainder MOD = (Y - YIN)
x X2 of instance DIV 0 of the divider.
r20115 CO: MUL 1 product Y / MUL 1 product Y
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
- - -
p20116 MUL 1 run-time group / MUL 1 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
5 9999 9999
p20117 MUL 1 run sequence / MUL 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
0 32000 280
p20118[0...1] CI: DIV 0 inputs / DIV 0 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
- - 0
r20119[0...2] CO: DIV 0 quotient / DIV 0 quotient
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
- - -

Table of Contents