Parameters
List of parameters
1-342
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for jogging incremental.
Dependency: Refer to: p2585, p2586, p2587, p2588, p2589, p2590
Description: Sets the signal source for the reference of the internal length units LU to motor revolution for rotary encoders and to
mm for linear encoders.
Dependency: Refer to: p0404, r2524, p2594
Note: The signal value is used to convert the length unit to the speed or velocity setpoint.
Description: Sets the signal source for the externally limited maximum velocity.
Index: [0] = Setpoint limit absolute
[1] = Setpoint limiting positive
[2] = Setpoint limiting negative
Dependency: Refer to: r2524, p2571, p2593
Warning: In order that the externally limited velocity can be effective for the EPOS operating modes, connector input p2593
must be correctly interconnected.
Description: Sets the signal source to start the "search for reference" or "flying referencing".
BI: p2595 = 0/1 signal
Referencing is started.
BI: p2595 = 1/0 signal
Referencing is interrupted.
Dependency: Refer to: p2597, p2598, p2599, r2684
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2591 BI: EPOS jogging incremental / Jog incr
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3610
Min Max Factory setting
- - 722.5
p2593 CI: EPOS LU/revolution LU/mm / LU/rev LU/mm
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3630
Min Max Factory setting
- - 2524[0]
p2594[0...2] CI: EPOS Maximum velocity externally limited / v_Max ext lim
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: p2000 Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3630
Min Max Factory setting
- - 0
p2595 BI: EPOS referencing start / Ref start
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612, 3625, 3614
Min Max Factory setting
- - 0