EasyManua.ls Logo

Siemens SINAMICS G120D - r2676 CO: EPOS actual task parameter; Task para act; r2677 CO: EPOS actual task mode; Task mode act; r2678 CO: EPOS external block change actual position; Ext BlckChg s_act; r2680 CO: EPOS clearance reference cam and zero mark; Clearance cam;ZM

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-364
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
6: GOTO
7: SET_O
8: RESET_O
9: JERK
Dependency: Refer to: p2621
Description: Displays the task parameter presently being processed in the "traversing blocks" operating mode.
Dependency: Refer to: p2622
Note: The following is displayed depending on the task:
FIXED STOP: Clamping torque (0 ... 65536 [0.01 Nm]) or clamping force (0 ... 65536 [N])
WAIT: Delay time [ms]
GOTO: Block number
SET_O: 1, 2, 3 --> direct output 1, 2 or 3 (both) is set
RESET_O: 1, 2, 3 --> direct output 1, 2 or 3 (both) is reset
JERK: 0 --> de-activate, 1 --> activate
Description: Displays the task mode presently being processed.
Dependency: Refer to: p2623
Description: Displays the actual position for the following events:
- external block change via measuring probe (p2632 = 0, BI: p2661 = 0/1 signal).
- external block change via BI: p2633 (p2632 = 1, BI: p2633 = 0/1 signal).
- activate traversing task (BI: p2631 = 0/1 signal).
Dependency: Refer to: p2631, p2632, p2633, p2661
Description: Displays the clearance determined between the reference cam and zero mark in the search for reference.
r2676 CO: EPOS actual task parameter / Task para act
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
- - -
r2677 CO: EPOS actual task mode / Task mode act
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
- - -
r2678 CO: EPOS external block change actual position / Ext BlckChg s_act
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3615, 3616, 3620
Min Max Factory setting
- [LU] - [LU] - [LU]
r2680 CO: EPOS clearance reference cam and zero mark / Clearance cam/ZM
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
- [LU] - [LU] - [LU]

Table of Contents