Parameters
List of parameters
1-196
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Note: Re bit 16 = 1:
Encoderless open-loop controlled operation not active.
Re bit 16 = 0:
Encoderless open-loop controlled operation active.
Description: Displays the current controller status word.
Description: Sets the time constant for the speed setpoint filter 1 (PT1).
Bit field: Bit Signal name 1 signal 0 signal FP
00 U/f control active Yes No -
01 Encoderless operation active Yes No -
02 Torque control active Yes No 6030,
6060,
8010
03 Speed control active Yes No 6040
05 Speed controller I component frozen Yes No 6040
06 Speed controller I component set Yes No 6040
07 Torque limit reached Yes No 6060
08 Upper torque limit active Yes No 6060
09 Lower torque limit active Yes No 6060
10 Droop enabled Yes No 6030
11 Speed setpoint limited Yes No 6030
12 Ramp-function generator set Yes No -
13 Encoderless operation due to a fault Yes No -
14 I/f control active Yes No -
15 Torque limit reached (without pre-control) Yes No 6060
16 Encoderless open-loop controlled operation
not active
Yes No -
17 Speed limiting control active Yes No 6640
r1408.0...14 CO/BO: Status word current controller / ZSW I_ctrl
Access level: 4 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2530
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Current controller act Active Not active -
01 Id control I component limiting Active Not active 6714
03 Voltage limiting Active Not active 6714
10 Speed adaptation limiting Active Not active -
11 Speed adaptation speed deviation Out tolerance In tolerance 6719
12 Motor stalled Yes No -
13 Separately excited synchronous motor is
excited
Yes No -
14 Current model FEM: magnetizing excitation
current limited to 0
Yes No -
p1416[0...n] Speed setpoint filter 1 time constant / n_set_filt 1 T
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 1700, 6030
Min Max Factory setting
0.00 [ms] 5000.00 [ms] 0.00 [ms]