List of parameters
Parameters
1-383
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Display and connector output for the actual value XIST1_ERW.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p4652, r4654, p4655
Description: Display and binector output to reset XIST1_ERW.
Dependency: Refer to: p4652, r4653, p4655
Note: The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
Description: Sets the signal source to reset XIST1_ERW (CO: r4653).
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p4652, r4653, r4654
Note: The reset of XIST1_ERW depends on the selected mode (p4652).
Description: Sets the permissible tolerance in encoder pulses for the zero mark distance in the context of zero mark monitoring.
Causes fault F3x100 to appear less frequently.
Dependency: Refer to: p0430
Refer to: F31100
Note: The parameter is activated using p0430.21 = 1 (zero mark tolerance).
r4653[0...2] CO: XIST1_ERW actual value / XIST1_ERW actval
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4750
Min Max Factory setting
- - -
r4654.0...16 CO/BO: XIST1_ERW status / XIST1_ERW stat
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4750
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Encoder 1 XIST1_ERW reset High Low -
08 Encoder 2 XIST1_ERW reset High Low -
16 Encoder 3 XIST1_ERW reset High Low -
p4655[0...2] BI: XIST1_ERW reset signal source / XIST1_ERW resS_src
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4750
Min Max Factory setting
- - 0
p4680[0...n] Zero mark monitoring tolerance permissible / ZM_monit tol perm
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(4) Scaling: - Dyn. index: EDS, p0140
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 1000 4