Siemens SINAMICS G120D - r9794[0...19] SI crosswise comparison list (processor 1); SI CDC_list P1; r9795 SI diagnostics STOP F (processor 1); SI diag STOP F P1; r9798 SI actual checksum SI parameters (processor 1); SI act chksm P1; p9799 SI setpoint checksum SI parameters (processor 1); SI setp_chksm P1

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-443
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the numbers of the data items that are currently being compared crosswise on processor 1.
The content of the list of crosswise-compared data is dependent upon the particular application.
Note: Example:
r9794[0] = 1 (monitoring clock cycle)
r9794[1] = 2 (enable safety functions)
r9794[2] = 3 (F-DI changeover, tolerance time)
...
A complete list of numbers for crosswise-compared data items appears in fault F01611.
Description: Displays the number of the cross-compared data item which caused STOP F on processor 1.
Dependency: Refer to: F01611
Note: A complete list of numbers for crosswise-compared data items appears in fault F01611.
Description: Displays the checksum for the Safety Integrated parameters checked using checksums on processor 1 (actual
checksum).
Dependency: Refer to: p9799, r9898
Description: Sets the checksum for the Safety Integrated parameters checked using checksums on processor 1 (setpoint check-
sum).
Dependency: Refer to: r9798, p9899
r9794[0...19] SI crosswise comparison list (processor 1) / SI CDC_list P1
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2802
Min Max Factory setting
- - -
r9795 SI diagnostics STOP F (processor 1) / SI diag STOP F P1
Access level: 2 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2802
Min Max Factory setting
- - -
r9798 SI actual checksum SI parameters (processor 1) / SI act chksm P1
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2800
Min Max Factory setting
- - -
p9799 SI setpoint checksum SI parameters (processor 1) / SI setp_chksm P1
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2800
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex