List of parameters
Parameters
1-87
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Dependency: Refer to: p0437, p0601
Note: A value of zero is displayed if an encoder is not present.
Re bit 11:
When the property is set, the following parameters can be changed without the actual value in the encoder interface
becoming invalid (state r0481.14 = 1 "parking encoder active"):
p0314, p0315, p0430, p0431, p0441, p0442, p0443, p0444, p0445
Re bit 12:
The extended functions can be configured using p0437.
Re bit 13:
Encoder faults can be acknowledged via Gn_STW.15.
Re bit 14:
Only for internal Siemens use.
Description: Displays the extended properties supported by the Sensor Module.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p0437
Note: A value of zero is displayed if an encoder is not present.
Re bit 09:
Parameter p0426 or p0439 has been modified. These functions are not supported by the connected Sensor Mod-
ule.
r0459[0...2] Sensor Module properties extended / SM prop ext
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Data logger Yes No -
01 Zero mark edge detection Yes No -
02 Correction position actual value XIST1 Yes No -
04 Edge evaluation bit 0 Yes No -
05 Edge evaluation bit 1 Yes No -
06 Freeze the speed actual value for dn/dt
errors
Yes No -
07 Accumulate uncorrected encoder pulses Yes No -
09 Function p0426, p0439 supported Yes No -
10 Pulse/direction interface Yes No -
11 Fault handling after PROFIdrive Yes No -
12 Activate additional messages Yes No -
13 Absolute position for incremental encoder
supported
Yes No -
14 Spindle functionality Yes No -
15 Additional temperature sensor available Yes No -
16 Internal encoder temperature available Yes No -
25 Deselect monitoring multiturn representa-
tion in Gx_XIST2
Yes No -
26 Track monitoring de-selection Yes No -
28 EnDat linear encoder monitoring incremen-
tal/absolute
Yes No -
29 EnDat encoder initialization with high accu-
racy
Yes No -
31 Analog unipolar track monitoring Yes No -