Siemens SINAMICS G120D - r1763 Motor model deviation component 2; MotMod dev comp 2; p1764[0...n] Motor model without encoder speed adaptation Kp; MotMod woE n_adaKp; r1765 Motor model speed adaptation Kp effective; MotM n_ada Kp act; p1767[0...n] Motor model without encoder speed adaptation Tn; MotMod woE n_adaTn

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-228
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Index: [0] = Deviation model 1
[1] = Deviation model 2
Description: Induction motor (ASM):
Displays the referred real system deviation for the adaptation circuit of the motor model.
Permanent magnet synchronous motor (PEM):
Not used.
Description: Sets the proportional gain of the controller for speed adaptation without encoder.
Description: Displays the effective proportional gain of the controller for the speed adaptation.
Description: Sets the integral time of the controller for speed adaptation without encoder
Description: Displays the effective gain of the integral component of the controller for speed adaptation.
r1763 Motor model deviation component 2 / MotMod dev comp 2
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
p1764[0...n] Motor model without encoder speed adaptation Kp / MotMod woE n_adaKp
Access level: 4 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6730
Min Max Factory setting
0.000 100000.000 1000.000
r1765 Motor model speed adaptation Kp effective / MotM n_ada Kp act
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2001 Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
p1767[0...n] Motor model without encoder speed adaptation Tn / MotMod woE n_adaTn
Access level: 4 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6730
Min Max Factory setting
1 [ms] 200 [ms] 4 [ms]
r1768 Motor model speed adaptation Vi effective / MotM n_ada Vi act
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2001 Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -