List of parameters
Parameters
1-109
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the number of inputs and outputs
Index: [0] = Number of digital inputs
[1] = Number of digital outputs
[2] = Number of digital input/outputs bidirectional
[3] = Number of analog inputs
[4] = Number of analog outputs
Description: Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x prior to switching from the simulation mode
(p0795.x = 1) to the terminal mode (p0795.x = 0).
Note: AI: Analog Input
DI: Digital Input
Description: Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x prior to switching from the simulation mode
(p0795.x = 1) to the terminal mode (p0795.x = 0).
Note: DI: Digital Input
r0720[0...4] CU number of inputs and outputs / CU I/O count
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 1510
Min Max Factory setting
- - -
r0721 CU digital inputs terminal actual value / CU DI actual value
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 2 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 1508, 2218, 2222
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X07.4) High Low -
01 DI 1 (X07.2) High Low -
02 DI 2 (X08.4) High Low -
03 DI 3 (X08.2) High Low -
04 DI 4 (X09.4) High Low -
05 DI 5 (X09.2) High Low -
11 DI 11 (X10.3) AI 0 High Low -
12 DI 12 (X10.4) AI 1 High Low -
r0721 CU digital inputs terminal actual value / CU DI actual value
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 2 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 1508, 2218, 2222
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X07.4) High Low -
01 DI 1 (X07.2) High Low -
02 DI 2 (X08.4) High Low -
03 DI 3 (X08.2) High Low -
04 DI 4 (X09.4) High Low -
05 DI 5 (X09.2) High Low -