List of parameters
Parameters
1-349
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the velocity for the traversing block.
Dependency: The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2619, p2620, p2621, p2622, p2623, p2624, p2646
Note: The velocity can be influenced using the velocity override (p2646).
Description: Sets the acceleration override for the traversing block.
The override refers to the maximum acceleration (p2572).
Dependency: The number of indices depends on p2615.
Refer to: p2572, p2615, p2616, p2617, p2618, p2620, p2621, p2622, p2623, p2624
Description: Sets the deceleration override for the traversing block.
The override refers to the maximum deceleration (p2573).
Dependency: The number of indices depends on p2615.
Refer to: p2573, p2615, p2616, p2617, p2618, p2619, p2621, p2622, p2623, p2624
Notice: If, when calculating the traversing profile, it is identified that the target position of the next block with the pro-
grammed deceleration override will not be reached without direction reversal (flying block change), then the old
(actual) deceleration override remains effective.
Description: Sets the required task for the traversing block.
Value: 1: POSITIONING
2: FIXED STOP
3: ENDLESS_POS
4: ENDLESS_NEG
5: WAITING
6: GOTO
7: SET_O
8: RESET_O
9: JERK
p2618[0...n] EPOS traversing block velocity / Trav_block v
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: U, T Scaling: - Dyn. index: p2615
Units group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
1 [1000 LU/min] 40000000 [1000 LU/min] 600 [1000 LU/min]
p2619[0...n] EPOS traversing block acceleration override / Trav_block a_over
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: p2615
Units group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
1.0 [%] 100.0 [%] 100.0 [%]
p2620[0...n] EPOS traversing deceleration override / Trav_block -a_over
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: p2615
Units group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
1.0 [%] 100.0 [%] 100.0 [%]
p2621[0...n] EPOS traversing block task / Trav_block task
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer16
Can be changed: U, T Scaling: - Dyn. index: p2615
Units group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
1 9 1