EasyManua.ls Logo

Siemens SINAMICS G120D - p20252 PT1 1 smoothing time constant in ms; PT1 1 T_smooth ms; r20253 CO: PT1 1 output Y; PT1 1 output Y; p20254 PT1 1 run-time group; PT1 1 RTG; p20255 PT1 1 run sequence; PT1 1 RunSeq

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-514
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the smoothing time constant T in milliseconds of instance PT1 1 of the smoothing element.
Description: Display parameter for the smoothed output quantity Y of instance PT1 1 of the smoothing element.
Description: Setting parameter for the run-time group in which instance PT1 1 of the smoothing element is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance PT1 1 within the run-time group set in p20254.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X and of setting value SV of instance INT 0 of the integrator.
Index: [0] = Input X
[1] = Setting value SV
p20252 PT1 1 smoothing time constant in ms / PT1 1 T_smooth ms
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7262
Min Max Factory setting
0.00 340.28235E36 0.00
r20253 CO: PT1 1 output Y / PT1 1 output Y
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7262
Min Max Factory setting
- - -
p20254 PT1 1 run-time group / PT1 1 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7262
Min Max Factory setting
5 9999 9999
p20255 PT1 1 run sequence / PT1 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7262
Min Max Factory setting
0 32000 680
p20256[0...1] CI: INT 0 inputs / INT 0 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - 0

Table of Contents

Other manuals for Siemens SINAMICS G120D

Related product manuals