EasyManua.ls Logo

Siemens SINAMICS G120D - r9712 CO: SI Motion diagnostics pos. act. val. motor side (processor 1); SI Mtn s_act motP1; r9713[0...5] CO: SI Motion diagnostics position actual value load side; SI Mtn s_act load

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-431
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Dependency: Refer to: C01711
Note: SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
SLS: Safely-Limited Speed
Description: Displays the actual motor-side position actual value for the motion monitoring functions on processor 1.
Note: The display is updated in the safety monitoring clock cycle.
Description: Displays the actual load-side actual values of both monitoring channels and their difference.
Index: [0] = Load-side actual value on processor 1 (P1)
[1] = Load-side actual value on processor 2 (P2)
[2] = Load-side actual value difference P1 - P2
[3] = Load-side maximum actual value difference P1 - P2
[4] = Load-side actual value as safe position via PROFIsafe
[5] = Load-side additional actual value difference CU - second channel
Dependency: Refer to: r9708, r9724
Note: The value of this parameter is displayed in r9708 with units (mm or degrees).
The display is updated in the safety monitoring clock cycle.
Re index 0:
The display of the load-side position actual value on processor 1 is updated in the monitoring clock cycle.
Re index 1:
The display of the load-side position actual value on processor 2 is updated in the CDC clock cycle (r9724) and
delayed by one CDC clock cycle.
Re index 2:
The difference between the load-side position actual value on processor 1 and load-side position actual value on
processor 2 is updated in the CDC clock cycle (r9724) and delayed by one CDC clock cycle.
Re index 3:
The maximum difference between the load-side position actual value on processor 1 and the load-side position
actual value on processor 2.
Re index 4:
The content corresponds to the value in index 0.
CDC: Crosswise Data Comparison
r9712 CO: SI Motion diagnostics pos. act. val. motor side (processor 1) /
SI Mtn s_act motP1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r9713[0...5] CO: SI Motion diagnostics position actual value load side / SI Mtn s_act load
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -

Table of Contents