Parameters
List of parameters
1-414
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Only for internal Siemens service purposes.
Dependency: Refer to: r9406, r9407
Note: All indices from r9406 to r9408 designate the same parameter.
r9406[x] parameter number, parameter not accepted
r9407[x] parameter index, parameter not accepted
r9408[x] fault code, parameter not accepted
Description: Displays the number of modified parameters and those that have still not be saved for this drive object.
Dependency: Refer to: p0971
Notice: Inherent to the system, the list of the parameters to be backed up is empty after the following actions:
- Download
- Warm restart
- Factory setting
In these cases, a new parameter backup must be initiated, which is then the starting point for the list of modified
parameters.
Note: The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
Description: Displays the parameters whose parameter would have to be changed during a units changeover.
Dependency: Refer to: F07088
Description: Displays the set valid macro.
Note: A value of 0 is displayed if a parameter set by a macro is changed.
r9408[0...19] PS file fault code parameter not transferred / PS fault code
Access level: 4 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r9409 Number of parameters to be saved / Qty par to save
Access level: 4 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r9451[0...29] Units changeover adapted parameters / Unit_chngov par
Access level: 4 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r9463 Actual macro / Actual macro
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 999999 -