Siemens SINAMICS G120D - p20147 MFP 1 run sequence; MFP 1 RunSeq; p20148 BI: PCL 0 input pulse I; PCL 0 inp_pulse I; p20149 PCL 0 pulse duration in ms; PCL 0 pulse_dur ms; r20150 BO: PCL 0 output Q; PCL 0 output Q

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-492
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Setting parameter for the run sequence of instance MFP 1 within the run-time group set in p20146.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for the input pulse I of instance PCL 0 of the pulse shortener.
Description: Setting parameter for pulse duration T in milliseconds of instance PCL 0 of the pulse shortener.
Description: Display parameter for output pulse Q of instance PCL 0 of the pulse shortener.
Description: Setting parameter for the run-time group in which the instance PCL 0 of the pulse shortener is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
p20147 MFP 1 run sequence / MFP 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
0 32000 380
p20148 BI: PCL 0 input pulse I / PCL 0 inp_pulse I
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
- - 0
p20149 PCL 0 pulse duration in ms / PCL 0 pulse_dur ms
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
0.00 5400000.00 0.00
r20150 BO: PCL 0 output Q / PCL 0 output Q
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
- - -
p20151 PCL 0 run-time group / PCL 0 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
5 9999 9999