Description: Sets the signal source for the signal "travel to fixed stop active".
BI: p2552 = 1 signal:
The activity associated with travel to fixed stop is signaled and the detection of the fixed stop is started via the max-
imum following error (p2634).
Dependency: Refer to: r2683
Description: Sets the signal source for the signal "fixed stop reached".
BI: p2553 = 1 signal:
When the fixed stop is reached, this is signaled and the fixed stop monitoring window is activated.
Dependency: Refer to: r2683
Description: Sets the signal source for the signal "traversing command active".
BI: p2554 = 1 signal:
It is signaled that positioning is active and therefore the positioning monitoring is not activated with the signal "set-
point present" (p2551).
Dependency: Refer to: p2551, r2684
Description: Sets the signal source for the reference of the internal length units LU to motor revolution for rotary encoders and to
mm for linear encoders.
Dependency: Refer to: p0404, r2524
Note: The signal value is used to convert the length unit to the speed or velocity setpoint.
p2552 BI: LR signal travel to fixed stop active / Signal TfS act
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4025
Min Max Factory setting
- - 2683.14
p2553 BI: LR signal fixed stop reached / Signal fixed stop
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4025
Min Max Factory setting
- - 2683.12
p2554 BI: LR signal traversing command active / Sig trav_cmnd act
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4020
Min Max Factory setting
- - 2684.15
p2555 CI: LR LU/revolution LU/mm / LU/rev LU/mm
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4015
Min Max Factory setting
- - 2524[0]