Safety Integrated Basic Functions
Function diagrams
2-639
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Fig. 2-54 2812 – F-DI: Fail-safe digital input
- 2812 -
Function diagram
87654321
fp_2812_97_04.vsd
Safety Integrated Basic Functions
SINAMICS G120D
12.12.2012 V4.6
F-DI (Fail-safe Digital Input)
1L+
X09.1
DI 4X09.4
FEX09.5
DI 5X09.2
1MX09.3
SI STO t_debou P1
0.00 ... 100.00 [ms]
p9651 (1.00)
SI STO t_debou P2
0.00 ... 100000.00 [μs]
p9851 (0.00)
1MX09.3
F-DI: Fail-safe Digital Input
FE: Functional Earth
&
F-DI0
=1
[2810.4]
T0
SI F-DI_chg tol P1
0.00 ... 2000.00 [ms]
p9650 (500.00)