Function diagrams
Safety Integrated Extended Functions
2-646
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Fig. 2-60 2850 – Fail-safe digital inputs (F-DI 0 ... F-DI 2)
- 2850 -
Function diagram
87654321
fp_2850_97_04.vsd
Safety Integrated Extended Functions
SINAMICS G120D
12.12.2012 V4.6
Fail-safe Digital Inputs (F-DI 0 ... F-DI 2)
&
F-DI 2
[2855.2]
C01770
T0
=1
SI discrp t_mon P1
1.00 ... 2000.00 [ms]
p10002 (500.00)
SI DI status P1
r10051
r10051
.2
SI DI status P2
r10151
r10151
.2
SI discr t_mon P2
1.00 ... 2000.00 [ms]
p10102 (500.00)
SI DI t_debounceP1
0.00 ... 100.00 [ms]
p10017 (1.00)
SI DI t_debounceP2
0.00 ... 100.00 [ms]
p10117 (1.00)
&
F-DI 1
[2855.2]
C01770
T0
=1
SI discrp t_mon P1
1.00 ... 2000.00 [ms]
p10002 (500.00)
SI DI status P1
r10051
r10051
.1
SI DI status P2
r10151
r10151
.1
SI discr t_mon P2
1.00 ... 2000.00 [ms]
p10102 (500.00)
SI DI t_debounceP1
0.00 ... 100.00 [ms]
p10017 (1.00)
SI DI t_debounceP2
0.00 ... 100.00 [ms]
p10117 (1.00)
&
F-DI 0
[2855.2]
C01770
T0
=1
SI discrp t_mon P1
1.00 ... 2000.00 [ms]
p10002 (500.00)
SI DI status P1
r10051
r10051
.0
SI DI status P2
r10151
r10151
.0
SI discr t_mon P2
1.00 ... 2000.00 [ms]
p10102 (500.00)
SI DI t_debounceP1
0.00 ... 100.00 [ms]
p10017 (1.00)
SI DI t_debounceP2
0.00 ... 100.00 [ms]
p10117 (1.00)
F-DI: Fail-safe Digital Input
F-DI 0
Discrepancy error
Discrepancy error
Discrepancy error
1L+
X07.1
DI 0X07.4
FEX07.5
DI 1X07.2
1MX07.3
1MX07.3
F-DI 1
1L+
X08.1
DI 2X08.4
FEX08.5
DI 3
X08.2
1MX08.3
1MX08.3
F-DI 2
1L+
X09.1
DI 4X09.4
FEX09.5
DI 5X09.2
1MX09.3
1MX09.3