Siemens SINAMICS G120D - p9548 SI Motion SAM actual velocity tolerance (processor 1); SI mtn SAM tol P1; p9551 SI Motion SLS changeover delay time (processor 1); SI Mtn SLS t P1; p9556 SI Motion pulse suppression delay time (processor 1); SI Mtn IL t_del P1; p9558 SI Motion acceptance test mode time limit (processor 1); SI Mtn acc t P1

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-420
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Note: The velocity hysteresis is effective only if the function is enabled (p9501.16 = 1).
The parameter is included in the crosswise data comparison of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description: Sets the velocity tolerance for the "SAM" function.
Dependency: Refer to: C01706
Note: SAM: Safe Acceleration Monitor (safe acceleration monitoring)
Description: Sets the delay time for the SLS changeover for the function "safely limited speed" (SLS).
When transitioning from a higher to a lower safely-limited velocity/speed stage, within this delay time, the "old"
velocity stage remains active.
Even if SLS is activated from non safety-related operation, then this delay is still applied.
Note: SLS: Safely-Limited Speed
Description: Sets the delay time for the safe pulse suppression after STOP B.
In the case of encoderless motion monitoring functions with safe brake ramp monitoring (p9506 = 1) and the OFF3
ramp enabled at the same time (p9507.3 = 0), the parameter has no effect.
Dependency: Refer to: p9560
Refer to: C01701
Description: Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency: Refer to: C01799
p9548 SI Motion SAM actual velocity tolerance (processor 1) / SI mtn SAM tol P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00 [rpm] 120000.00 [rpm] 300.00 [rpm]
p9551 SI Motion SLS changeover delay time (processor 1) / SI Mtn SLS t P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2819, 2820
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9556 SI Motion pulse suppression delay time (processor 1) / SI Mtn IL t_del P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2819
Min Max Factory setting
0.00 [ms] 3600000.00 [ms] 600000.00 [ms]
p9558 SI Motion acceptance test mode time limit (processor 1) / SI Mtn acc t P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
5000.00 [ms] 100000.00 [ms] 40000.00 [ms]