EasyManua.ls Logo

Siemens SINAMICS G120D - p0446[0...n] Encoder SSI number of bits before the absolute value; Enc SSI bit before; p0447[0...n] Encoder SSI number of bits absolute value; Enc SSI bit val; p0448[0...n] Encoder SSI number of bits after the absolute value; Enc SSI bit after; p0449[0...n] Encoder SSI number of bits filler bits; Enc SSI fill bits

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-84
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the number of bits before the absolute value in the SSI protocol.
Caution: This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note: For example, error bit, alarm bit or parity bit can be positioned at these bits.
Description: Sets the number of bits for the absolute value in the SSI protocol.
Caution: This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description: Sets the number of bits after the absolute value in the SSI protocol.
Caution: This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note: For example, error bit, alarm bit or parity bit can be positioned at these bits.
Description: Sets the number of filler bits for double absolute value transfer in the SSI protocol.
Dependency: Refer to: p0429
Caution: This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note: This parameter is only of significance for p0429.2 = 1.
p0446[0...n] Encoder SSI number of bits before the absolute value / Enc SSI bit before
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C(4) Scaling: - Dyn. index: EDS, p0140
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 65535 0
p0447[0...n] Encoder SSI number of bits absolute value / Enc SSI bit val
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C(4) Scaling: - Dyn. index: EDS, p0140
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 65535 25
p0448[0...n] Encoder SSI number of bits after the absolute value / Enc SSI bit after
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C(4) Scaling: - Dyn. index: EDS, p0140
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 65535 0
p0449[0...n] Encoder SSI number of bits filler bits / Enc SSI fill bits
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C(4) Scaling: - Dyn. index: EDS, p0140
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 65535 1

Table of Contents