SINAMICS G120D List Manual (LH14), 01/2013
Index: [0] = Quotient Y
[1] = Integer number quotient YIN
[2] = Div remainder MOD
Description: Display parameter for the signal QF that the divisor X2 of instance DIV 0 of the divider is zero.
X2 = 0.0 => QF = 1
Description: Setting parameter for the run-time group in which instance DIV 0 of the divider is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance DIV 0 within the run-time group set in p20121.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of dividend X1 and divisor X2 of instance DIV 1 of the divider.
Index: [0] = Dividend X0
[1] = Divisor X1
r20120 BO: DIV 0 divisor is zero QF / DIV 0 divisor=0 QF
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
- - -
p20121 DIV 0 run-time group / DIV 0 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
5 9999 9999
p20122 DIV 0 run sequence / DIV 0 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
0 32000 300
p20123[0...1] CI: DIV 1 inputs / DIV 1 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
- - 0