Siemens SINAMICS G120D - r0395[0...n] Actual stator resistance; R_stator act; r0396[0...n] Actual rotor resistance; R_rotor act; p0397[0...n] Angle magnetic decoupling maximum angle; Magn decpl max_ang; p0400[0...n] Encoder type selection; Enc_typ sel

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-74
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the actual stator resistance (phase value).
The parameter value also contains the temperature-independent cable resistance.
Dependency: In the case of induction motors the parameter is also affected by the motor temperature model.
Refer to: p0350, p0352, p0620
Note: In each case, only the stator resistance of the active Motor Data Set is included with the stator temperature of the
thermal motor model.
Description: Displays the actual rotor resistance (phase value).
The parameter is affected by the motor temperature model.
Dependency: Refer to: p0354, p0620
Note: In each case, only the rotor resistance of the active Motor Data Set is included with the rotor temperature of the
thermal motor model.
This parameter is not used for synchronous motors (p0300 = 2xx).
Description: Maximum angle when calculating the polynomial function to decouple the magnetic flux axes for permanent-magnet
synchronous motors (see p0398, p0399).
Description: Selects the encoder from the list of encoder types supported.
Value: 0: No encoder
3001: 1024 HTL A/B R
3003: 2048 HTL A/B R
3005: 1024 HTL A/B
3007: 2048 HTL A/B
9999: User-defined
r0395[0...n] Actual stator resistance / R_stator act
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0396[0...n] Actual rotor resistance / R_rotor act
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Units group: - Unit selection: - Func. diagram: 6730
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
p0397[0...n] Angle magnetic decoupling maximum angle / Magn decpl max_ang
Access level: 4 Calculated: p0340 = 1,2 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: MDS
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.0 [°] 90.0 [°] 90.0 [°]
p0400[0...n] Encoder type selection / Enc_typ sel
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 1 Calculated: - Data type: Integer16
Can be changed: C(1, 4) Scaling: - Dyn. index: EDS
Units group: - Unit selection: - Func. diagram: 1580, 4704
Min Max Factory setting
0 9999 0