Siemens SINAMICS G120D - p1530[0...n] Power limit motoring; P_max mot; p1531[0...n] Power limit regenerative; P_max gen; r1533 Current limit torque-generating total; Iq_max total; r1536[0...1] Current limit maximum torque-generating current; Isq_max

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-212
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the power limit when motoring.
Dependency: Refer to: p0500, p1531
Note: The power limit is limited to 300% of the rated motor power.
Description: Sets the regenerative power limit.
Dependency: Refer to: r0206, p0500, p1530
Note: The power limit is limited to 300% of the rated motor power.
For power units without energy recovery capability, the regenerative power limit is preset to 30 % of the power
r0206[0]. For a braking resistor connected to the DC link (p0219 > 0), the power limit when generating is automati-
cally adapted.
For power units with energy recovery, the parameter is limited to the negative value of r0206[2].
Description: Displays the maximum torque/force generating current as a result if all current limits.
Description: Displays the maximum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
Index: [0] = Limited
[1] = Unlimited
Description: Displays the minimum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
p1530[0...n] Power limit motoring / P_max mot
Access level: 2 Calculated: p0340 = 1,3,5 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: 14_5 Unit selection: p0505 Func. diagram: 6640
Min Max Factory setting
0.00 [kW] 100000.00 [kW] 0.00 [kW]
p1531[0...n] Power limit regenerative / P_max gen
Access level: 2 Calculated: p0340 = 1,3,5 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: 14_5 Unit selection: p0505 Func. diagram: 6640
Min Max Factory setting
-100000.00 [kW] -0.01 [kW] -0.01 [kW]
r1533 Current limit torque-generating total / Iq_max total
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2002 Dyn. index: -
Units group: 6_2 Unit selection: p0505 Func. diagram: 5640, 5722, 6640
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1536[0...1] Current limit maximum torque-generating current / Isq_max
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2002 Dyn. index: -
Units group: 6_2 Unit selection: p0505 Func. diagram: 6640, 6710
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1537[0...1] Current limit minimum torque-generating current / Isq_min
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2002 Dyn. index: -
Units group: 6_2 Unit selection: p0505 Func. diagram: 6640, 6710
Min Max Factory setting
- [Arms] - [Arms] - [Arms]