List of parameters
Parameters
1-509
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Setting parameter for the run sequence of instance NSW 1 within the run-time group set in p20226.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X of instance LIM 0 of the limiter.
Description: Setting parameter for the upper limit value LU of instance LIM 0 of the limiter.
Description: Setting parameter for the lower limit value LL of instance LIM 0 of the limiter.
Description: Display parameter for the limited output quantity Y of instance LIM 0 of the limiter.
p20227 NSW 1 run sequence / NSW 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
0 32000 620
p20228 CI: LIM 0 input X / LIM 0 input X
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7260
Min Max Factory setting
- - 0
p20229 LIM 0 upper limit value LU / LIM 0 upper lim LU
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7260
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
p20230 LIM 0 lower limit value LL / LIM 0 lower lim LL
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7260
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
r20231 CO: LIM 0 output Y / LIM 0 output Y
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7260
Min Max Factory setting
- - -