EasyManua.ls Logo

Siemens SINAMICS G120D - r0479[0...2] CO: Diagnostics encoder position actual value Gn_XIST1; Diag Gn_XIST1; p0480[0...2] CI: Encoder control word Gn_STW signal source; Enc Gn_STW S_src

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-88
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the encoder actual position value Gn_XIST1 according to PROFIdrive for diagnostics.
In contrast to r0482, the value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Caution: Following ramping-up or after a data set changeover, the new value is present at connector inputs which are inter-
connected to connector output r0479 and under certain circumstances take 100 ms to become available.
Reason:
These interconnections are updated in the background, unlike interconnections involving other connector outputs
(e.g. CO: r0482).
The value is immediately available when non-cyclically reading r0479 (e.g. via the expert list).
Description: Sets the signal source for the encoder control word Gn_STW according to PROFIdrive.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description: Sets the signal source for the encoder control word Gn_STW according to PROFIdrive.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
r0479[0...2] CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
Access level: 3 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4704
Min Max Factory setting
- - -
p0480[0...2] CI: Encoder control word Gn_STW signal source / Enc Gn_STW S_src
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4720, 4750
Min Max Factory setting
- - [0] 0
[1] 0
[2] 0
p0480[0...2] CI: Encoder control word Gn_STW signal source / Enc Gn_STW S_src
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4720, 4750
Min Max Factory setting
- - [0] 2520[0]
[1] 2520[1]
[2] 2520[2]