List of parameters
Parameters
1-351
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the traversing blocks for sorting corresponding to their block number.
Procedure: Set p2624 = 0 --> 1.
Sorting is started and the parameters are automatically reset to zero once the operation has been completed.
Dependency: Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623
Note: After sorting, the traversing blocks are written at the beginning of the memory in increasing sequence without any
gaps.
Description: Sets the signal source to select the traversing block, bit 0.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2626, p2627, p2628
Description: Sets the signal source to select the traversing block, bit 1.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2627, p2628
Description: Sets the signal source to select the traversing block, bit 2.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2628
Description: Sets the signal source to select the traversing block, bit 3.
p2624 EPOS traversing block sorting / Trav_block sort
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
0 1 0
p2625 BI: EPOS traversing block selection bit 0 / Trav_blk sel bit 0
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2626 BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2627 BI: EPOS traversing block selection bit 2 / Trav_blk sel bit 2
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2628 BI: EPOS traversing block selection bit 3 / Trav_blk sel bit 3
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0