List of parameters
Parameters
1-479
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the signal source of input quantity I of instance NOT 3 of the inverter.
Description: Display parameter for the inverted output of instance NOT 3 of the inverter.
Description: Setting parameter for the run-time group in which the instance NOT 3 of the inverter is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NOT 3 within the run-time group set in p20092.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20090 BI: NOT 3 input I / NOT 3 input I
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - 0
r20091 BO: NOT 3 inverted output / NOT 3 inv output
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - -
p20092 NOT 3 run-time group / NOT 3 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
1 9999 9999
p20093 NOT 3 run sequence / NOT 3 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
0 32000 190