Siemens SINAMICS G120D - p2692 CO: EPOS acceleration override, fixed setpoint; a_over fixed val; p2693 CO: EPOS deceleration override, fixed setpoint; ­a_over fixed val; p2730[0...3] BI: LR pos. actual value preprocessing activate neg. corr. (edge); ActV_prep neg corr; p2731 BI: LR reduce I component; Reduce I comp

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-368
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets a fixed setpoint for the acceleration override.
Dependency: Refer to: p2572, p2644
Note: As standard, the following BICO interconnection is established: CI: p2644 = r2692
The percentage value refers to the maximum acceleration (p2572).
Description: Sets a fixed setpoint for the deceleration override.
Dependency: Refer to: p2573, p2645
Note: As standard, the following BICO interconnection is established: CI: p2645 = r2693
The percentage value refers to the maximum deceleration (p2573).
Description: Sets the signal source for the function "activate position actual value preprocessing, negative corrective value
(edge)".
0/1 signal:
The correction value available via CI: p2513 is negated and activated.
Index: [0] = Cl-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2513, r2684
Description: Sets the signal source for reducing the I component to zero in the position controller.
BI: p2731 = 1 signal:
The integrator input is set to zero and the integrator content is decreased to zero according to PT1. The PT1 time
constant corresponds to the integral time (p2539).
BI: p2731 = 0 signal:
The I component acts according to the set integral time (p2539).
Dependency: Refer to: p2539, r2559
p2692 CO: EPOS acceleration override, fixed setpoint / a_over fixed val
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3618
Min Max Factory setting
0.100 [%] 100.000 [%] 100.000 [%]
p2693 CO: EPOS deceleration override, fixed setpoint / -a_over fixed val
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3618
Min Max Factory setting
0.100 [%] 100.000 [%] 100.000 [%]
p2730[0...3] BI: LR pos. actual value preprocessing activate neg. corr. (edge) / ActV_prep neg corr
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4010, 4015
Min Max Factory setting
- - 0
p2731 BI: LR reduce I component / Reduce I comp
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4015
Min Max Factory setting
- - 1407.16