List of parameters
Parameters
1-207
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Caution: If the closed-loop torque control is not activated (p1300) and a change is made to closed-loop torque control
(p1501), OFF1 (p0840) does not have its own braking response but pulse suppression when standstill is detected
(p1226, p1227).
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: 0 signal: Closed-loop speed control
1 signal: Closed-loop torque control
Description: Sets the signal source for the torque setpoint for torque control.
Note: A change is made to closed-loop torque control if, in p1300, closed-loop torque control was selected or if the selec-
tion was made using the changeover source in p1501.
it is also possible to change over in operation using p1501.
Description: Displays the torque setpoint before entering the supplementary torque.
For closed-loop speed control, r1508 corresponds to the speed controller output; for closed-loop torque control,
r1508 corresponds to the torque setpoint of the signal source assigned in p1503.
Description: Sets the signal source for supplementary torque 1.
Description: Sets the signal source for scaling the supplementary torque 1.
Description: Sets the signal source for supplementary torque 2.
p1503[0...n] CI: Torque setpoint / M_set
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: p2003 Dyn. index: CDS, p0170
Units group: - Unit selection: - Func. diagram: 1700, 6060
Min Max Factory setting
- - 0
r1508 CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2003 Dyn. index: -
Units group: 7_1 Unit selection: p0505 Func. diagram: 6030, 6060, 6722
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
p1511[0...n] CI: Supplementary torque 1 / M_suppl 1
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: p2003 Dyn. index: CDS, p0170
Units group: - Unit selection: - Func. diagram: 5060, 6060
Min Max Factory setting
- - 0
p1512[0...n] CI: Supplementary torque 1 scaling / M_suppl 1 scal
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: CDS, p0170
Units group: - Unit selection: - Func. diagram: 5060, 6060
Min Max Factory setting
- - 0
p1513[0...n] CI: Supplementary torque 2 / M_suppl 2
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: p2003 Dyn. index: CDS, p0170
Units group: - Unit selection: - Func. diagram: 5060, 6060
Min Max Factory setting
- - 0