Loading...
Internal control/status words
Function diagrams
2-619
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Fig. 2-36 2511 – Status word 2 (r0053)
- 2511 -
Function diagram
87654321
fp_2511_97_51.vsd
Internal control/status words
SINAMICS G120D
12.12.2012 V4.6
Status word 2 (r0053)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
ZSW 2
r0053
r0053
1 = DC brake active
0 = DC brake not active
Bit No. Status word 2 (r0053)
1 = |n_act| > p1226 (n_standstill)
1 = |n_act| > p1080 (n_min)
1 = I_act >= p2170
1 = |n_act| > p2155
1 = |n_act| <= p2155
1 = |n_act| >= r1119 (n_set)
1 = Vdc <= p2172
1 = Vdc > p2172
1 = Ramping finished
1 = Techn. contr. out at lower limit
1 = Techn. contr. out at upper limit
Reserved
Reserved
Reserved
Reserved
r0053.0
r0053.1
r0053.4
r0053.5
r0053.11
r0053.2
r0053.6
r0053.9
r0053.3
r0053.7
r0053.8
r0053.10
[7017.5]
[2534.7]
[2534.7]
[2534.7]
[2534.7]
[2534.7]
[2534.7]
[2534.7]
[2534.7]
[3080.7]
[7958.7]
[7958.7]
ZSW monitor 1
r2197
r2197
.5
DCBRK ZSW
r1239
r1239
.8
ZSW monitor 1
r2197
r2197
.0
ZSW monitor 1
r2197
r2197
.8
ZSW monitor 1
r2197
r2197
.2
ZSW monitor 1
r2197
r2197
.1
ZSW monitor 1
r2197
r2197
.4
ZSW monitor 1
r2197
r2197
.9
ZSW monitor 1
r2197
r2197
.10
RFG ZSW
r1199
r1199
.2
Tec_ctrl status
r2349
r2349
.10
Tec_ctrl status
r2349
r2349
.11