List of parameters
Parameters
1-515
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the upper limit value LU of instance INT 0 of the integrator.
Description: Sets the lower limit value LL of instance INT 0 of the integrator.
Description: Sets the integrating time constant Ti in milliseconds of instance INT 0 of the integrator.
Description: Sets the signal source for the "accept setting value" signal of instant INT 0 of the integrator.
Description: Display parameter for output quantity Y of instance INT 0 of the integrator.
If LL>= LU, then the output quantity Y = LU.
p20257 INT 0 upper limit value LU / INT 0 upper lim LU
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
p20258 INT 0 lower limit value LL / INT 0 lower lim LL
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
p20259 INT 0 integrating time constant in ms / INT 0 T_Integr ms
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
0.00 340.28235E36 0.00
p20260 BI: INT 0 accept setting value S / INT 0 acc set val
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - 0
r20261 CO: INT 0 output Y / INT 0 output Y
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - -