EasyManua.ls Logo

Siemens SINAMICS G120D - Fig. 2-55 2819 - SS1: Safe Stop 1, internal STOP A, B, F

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety Integrated Extended Functions
Function diagrams
2-641
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Fig. 2-55 2819 – SS1: Safe Stop 1, internal STOP A, B, F
- 2819 -
Function diagram
87654321
fp_2819_97_58.vsd
Safety Integrated Extended Functions
SINAMICS G120D
12.12.2012 V4.6
SS1 (Safe Stop 1), Internal STOP A, B, F
STOP F
r9720.1
[2855.4]
r9721.12
T0
&
SS1 aktiv
r9722.1
[2855.5]
r9720.0
[2855.4]
[2804.1]
[2804.3]
[2810.4]
[2804.1]
SS1 deselection
STO deselection
STOP B active
STO initiate
[2840.5]
SI Mtn integ stat
r9722
r9722
.0
STO active
[2840.5]
SI Mtn integ stat
r9722
r9722
.1
SS1 active
SI Mtn IL t_del P2
0.00 ... 3600000000.00 [μs]
p9356 (600000000.00)
SI Mtn IL t_del P1
0.00 ... 3600000.00 [ms]
p9556 (600000.00)
STO cause: actual value missing
Actual value speed < p9360/p9560
STO selection because of missing
actual value (pulse suppression)
Safe Acceleration Monitor /
Safe Brake Ramp exceeded
<1> This applies to activation via F-DI (p9601.2 = 1, p9601.3 = 0).
<1>
<1>
<1>
[2858.6]
<2>
[2858.3]
<2>
[2858.3]
<2>
<2> This applies to activation via PROFIsafe (p9601.2 = 1, p9601.3 = 1).

Table of Contents