Description: Sets the signal source of minuend X1 and subtrahend X2 of instance SUB 0 of the subtractor.
Index: [0] = Minuend X1
[1] = Subtrahend X2
Description: Display parameter for the difference Y = X1 - X2 of instance SUB 0 of the subtractor.
Description: Setting parameter for the run-time group in which instance SUB 0 of the subtractor is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance SUB 0 within the run-time group set in p20104.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of minuend X1 and subtrahend X2 of instance SUB 1 of the subtractor.
p20102[0...1] CI: SUB 0 inputs / SUB 0 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
- - 0
r20103 CO: SUB 0 difference Y / SUB 0 difference Y
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
- - -
p20104 SUB 0 run-time group / SUB 0 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
5 9999 9999
p20105 SUB 0 run sequence / SUB 0 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
0 32000 240
p20106[0...1] CI: SUB 1 inputs / SUB 1 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
- - 0