Parameters
List of parameters
1-500
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Setting parameter for the run sequence of instance PST 1 within the run-time group set in p20186.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for set input S and reset input R of instance RSR 0 of the RS flipflop.
Index: [0] = Set S
[1] = Reset R
Description: Display parameter for output Q of instance RSR 0 of the RS flipflop
Description: Display parameter for inverted output QN of instance RSR 0 of the RS flipflop.
Description: Setting parameter for the run-time group in which instance RSR 0 of the RS flipflop is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
p20187 PST 1 run sequence / PST 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7234
Min Max Factory setting
0 7999 500
p20188[0...1] BI: RSR 0 inputs / RSR 0 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - 0
r20189 BO: RSR 0 output Q / RSR 0 output Q
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - -
r20190 BO: RSR 0 inverted output QN / RSR 0 inv outp QN
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - -
p20191 RSR 0 run-time group / RSR 0 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
1 9999 9999