Parameters
List of parameters
1-360
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Note: In the tracking mode, the position setpoint is taken from this connector input.
Description: Sets the signal source for the feedback signal "position actual value is valid".
BI: p2658 = 1 signal
The position actual value received via CI: p2657 is valid.
BI: p2658 = 0 signal
The position actual value received via CI: p2657 is invalid.
Dependency: Refer to: r2526, p2657
Note: While a 0 signal is present, the position setpoint (p2665) is held at the value of 0.
Description: Sets the signal source for the feedback signal "referencing active".
BI: p2659 = 1 signal
Referencing is active.
BI: p2659 = 0 signal
Referencing is not active.
Dependency: Refer to: r2526
Description: Sets the signal source for the measured value for the function "referencing".
Dependency: Refer to: r2523
Description: Sets the signal source for the feedback signal "measured value valid".
BI: p2661 = 1 signal
The measured value received via CI: p2660 is valid.
BI: p2661 = 0 signal
The measured value received via CI: p2660 is invalid.
Dependency: Refer to: r2526, p2660
p2658 BI: EPOS pos. actual value valid feedback signal / Pos valid feedback
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3635
Min Max Factory setting
- - 2526.0
p2659 BI: EPOS referencing active feedback signal / Ref act fdbk
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
- - 2526.1
p2660 CI: EPOS measured value referencing / Meas val ref
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Integer32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612, 3614
Min Max Factory setting
- - 2523[0]
p2661 BI: EPOS measured value valid feedback signal / MeasVal valid fdbk
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3612, 3614, 3615
Min Max Factory setting
- - 2526.2