EasyManua.ls Logo

Siemens SINAMICS G120D - Fig. 2-113 6640 - Current;power;torque limits

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vector control
Function diagrams
2-705
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Fig. 2-113 6640 – Current/power/torque limits
- 6640 -
Function diagram
87654321
fp_6640_97_53.vsd
Vector control
SINAMICS G120D
12.12.2012 V4.6
Current/power/torque limits
<1>
Iq
M
22
yx
-1
Min
Max Min
Min
Min
Max
+
+
+
+
[6722.1]
[6723.4]
[6724.4]
[6721.8]
[6730.1]
[6060.1] [6040.4]
[8012.1]
[3050.8]
<1>
[8016.8]
[6730.4]
[6731.4]
[6723.8]
[6722.1]
x
y
[6060.1] [6040.4]
[8012.1]
+
+
<2>
<1>
Max
[3050.8]
n
Iq
Current limiting
I_max reduction
I_max Power Module
Id_set total
Power limiting
Iq stall
calculation
Intervention by the Vdc controller.
Intervention when the speed limit is exceeded + 2 % n_rated.
Speed limiting
Kp from speed controller [6040.5]
Tn from speed controller [6040.6]
Speed limiting
controller
U_output max [Veff]
r0071
Mot L_leak total [mH]
r0377 [D]
Iq_max total [Aeff]
r1533
Current limit
0.00 ... 10000.00 [Aeff]
p0640 [D] (0.00)
Id_setp total [Aeff]
r1624
P_max gen
-100000.00 ... -0.01 [kW]
p1531 [D] (-0.01)
P_max mot
0.00 ... 100000.00 [kW]
p1530 [D] (0.00)
r1538
M_max upper eff [Nm]
r1539
M_max lower eff [Nm]
Isq_max [Aeff]
r1536
Isq_min [Aeff]
r1537
r1084
n_limit pos eff [1/min]
r1087
n_limit neg eff [1/min]
r1527
M_max low w/o offs [Nm]
r1526
M_max up w/o offs [Nm]
r0067
I_outp max [Aeff]
r0063
n_act [1/min]
[0]
r1548
Isq_max stall [Aeff]
[0]
r1548
Isq_max stall [Aeff]
[1]
Lower limit
Upper limit
Sign
+ or -
r1407.17
[2522.3]
1 = Speed limiting control
active
[6060.3]
Precontrol
Flux ctrl config
p1401
<2>
.7
[6630.8]
[6630.8]
[6710.1]
[6710.1]

Table of Contents

Other manuals for Siemens SINAMICS G120D