EasyManua.ls Logo

Siemens SINAMICS G120D - r9371 SI Motion acceptance test status (processor 2); SI Mtn acc_stat P2; p9381 SI Motion brake ramp reference value (processor 2); SI Mtn ramp ref P2; p9382 SI Motion brake ramp delay time (processor 2); SI Mtn rp t_del P2; p9383 SI Motion brake ramp monitoring time (processor 2); SI Mtn rp t_mon P2

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-409
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the status of the acceptance test mode.
Value: 0: [00 hex] Acc_mode inactive
12: [0C hex] Acc_mode not possible due to POWER ON fault
13: [0D hex] Acc_mode not possible due to incorrect ID in p9370
15: [0F hex] Acc_mode not possible due to expired Acc_timer
172: [AC hex] Acc_mode active
Dependency: Refer to: p9358, p9370
Refer to: C01799
Description: Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency: Refer to: p9382, p9383
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Description: Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency: Refer to: p9381, p9383
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Description: Sets the monitoring time to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency: Refer to: p9381, p9382
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
r9371 SI Motion acceptance test status (processor 2) / SI Mtn acc_stat P2
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0000 hex 00AC hex -
p9381 SI Motion brake ramp reference value (processor 2) / SI Mtn ramp ref P2
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
600.0000 [rpm] 240000.0000 [rpm] 1500.0000 [rpm]
p9382 SI Motion brake ramp delay time (processor 2) / SI Mtn rp t_del P2
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
10000.00 [µs] 99000000.00 [µs] 250000.00 [µs]
p9383 SI Motion brake ramp monitoring time (processor 2) / SI Mtn rp t_mon P2
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
500.00 [ms] 3600000.00 [ms] 10000.00 [ms]