EasyManua.ls Logo

Siemens SINAMICS G120D - r8572[0...39] Macro Connector Inputs (CI) for speed setpoints; Macro CI n_set; r8573[0...39] Macro Connector Inputs (CI) for torque setpoints; Macro CI M_set; r8585 Macro execution actual; Macro executed; r8854 PROFINET state; PN state

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-394
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency: Refer to: p1000
Note: For a value = 9999999, the following applies: The read operation is still running.
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency: Refer to: p1500
Note: For a value = 9999999, the following applies: The read operation is still running.
Description: Displays the macro currently being executed on the drive object.
Dependency: Refer to: p0015, p1000, p1500, r8570, r8571, r8572, r8573
Description: State display for PROFINET.
Value: 0: No initialization
1: Fatal fault
2: Initialization
3: Send configuration
4: Receive configuration
5: Non-cyclic communication
6: Cyclic communications but no setpoints (stop/no clock cycle)
255: Cyclic communication
r8572[0...39] Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
Access level: 4 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r8573[0...39] Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
Access level: 4 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r8585 Macro execution actual / Macro executed
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r8854 PROFINET state / PN state
CU240D-2_PN
CU240D-2_PN_F
CU250D-2_PN_F
Access level: 4 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 255 -