Parameters
List of parameters
1-506
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the signal source of input quantities I0 and I1 of instance BSW 1 of the binary changeover switch.
Index: [0] = Input I0
[1] = Input I1
Description: Sets the signal source of the switch setting I of instance BSW 1 of the binary changeover switch.
Description: Display parameter for output quantity Q of instance BSW 1 of the binary changeover switch.
Description: Setting parameter for the run-time group in which the instance BSW 1 of the binary changeover switch is to be
called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
p20213[0...1] BI: BSW 1 inputs / BSW 1 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0
p20214 BI: BSW 1 switch setting I / BSW 1 sw_setting
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0
r20215 BO: BSW 1 output Q / BSW 1 output Q
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - -
p20216 BSW 1 run-time group / BSW 1 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
1 9999 9999