List of parameters
Parameters
1-455
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Value: 0: No function
1: STO active
2: SS1 active
5: SLS active
6: SSM feedback signal active
7: Safe state
9: Internal event
12: SDI positive active
13: SDI negative active
Index: [0] = AND logic operation input 1
[1] = AND logic operation input 2
[2] = AND logic operation input 3
[3] = AND logic operation input 4
[4] = AND logic operation input 5
[5] = AND logic operation input 6
Note: F-DO: Failsafe Digital Output
Description: Activates the readback input for the safety digital output (F-DO)
The test mode for the particular safety digital output is set in p10047.
Dependency: Refer to: p10001, p10003, p10007, p10047
Note: The test stop is only performed if the safety output of the Control Unit is being used (see p10042).
Description: Sets the test stop mode for the safety digital output (F-DO)
Value: 2: Test mode 2 read back F-DO in DI (relay circuit)
3: Test mode 3 read back F-DO in DI (actuator with feedback signal)
4: Test mode 4 evaluation of two internal diagnostic signals
Dependency: Refer to: p10001, p10003, p10007, p10046
Note: The test stop is only performed if the safety output is being used (see p10042).
Description: Displays the monitoring status of the fail-safe digital inputs (F-DI).
The F-DIs that are being used by the Safety Integrated functions are displayed.
If the module used has fewer than 3 F-DIs, "Freely available" is displayed for the F-DIs which are not in use.
p10046 SI F-DO feedback signal input activation / SI F-DO FS act
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Test F-DO 0 Test active No test -
p10047 SI F-DO test stop mode / SI F-DO test mode
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
2 4 4
r10049 SI F-DI monitoring status (processor 1) / SI F-DI status P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -