List of parameters
Parameters
1-321
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the signal source to activate the function "set position actual value".
Index: [0] = Cl-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2515
Refer to: A07495, A07497
Warning: As long as the position actual value is set, encoder increments that are received are not evaluated. In this state, any
position difference cannot be corrected!
Notice: When the function "set position actual value" is activated while the function "reference mark search" or "measuring
probe evaluation" is activated, then the corresponding function is de-activated.
Note: BI: p2514 = 1 signal:
The position actual value is set to the setting value in CI: p2515. Alarm A07497 "position setting value activated" is
output. Encoder increments that are received in the meantime, are not taken into account.
BI: p2514 = 1/0 signal:
The position actual value preprocessing is activated and is based on the setting value.
Description: Sets the signal source for the setting value of the function "setting position actual value".
Index: [0] = Cl-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2514
Description: Sets the signal source for the position offset.
Index: [0] = Cl-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, r2667
p2514[0...3] BI: LR activate position actual value setting / s_act setting act
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4010
Min Max Factory setting
- - 0
p2515[0...3] CI: LR position actual setting setting value / s_act set setVal
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Integer32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4010
Min Max Factory setting
- - 0
p2516[0...3] CI: LR position offset / Position offset
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: U32 / Integer32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4010
Min Max Factory setting
- - [0] 2667[0]
[1] 0
[2] 0
[3] 0