Parameters
List of parameters
1-512
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Setting parameter for the run-time group in which instance LIM 1 of the limiter is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance LIM 1 within the run-time group set in p20242.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X and of setting value SV of instance PT1 0 of the smoothing element.
Index: [0] = Input X
[1] = Setting value SV
Description: Sets the signal source for the "accept setting value" signal of instant PT1 0 of the smoothing element.
Description: Sets the smoothing time constant T in milliseconds of instance PT1 0 of the smoothing element.
p20242 LIM 1 run-time group / LIM 1 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7260
Min Max Factory setting
5 9999 9999
p20243 LIM 1 run sequence / LIM 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7260
Min Max Factory setting
0 32000 650
p20244[0...1] CI: PT1 0 inputs / PT1 0 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7262
Min Max Factory setting
- - 0
p20245 BI: PT1 0 accept setting value S / PT1 0 acc set val
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7262
Min Max Factory setting
- - 0
p20246 PT1 0 smoothing time constant in ms / PT1 0 T_smooth ms
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7262
Min Max Factory setting
0.00 340.28235E36 0.00