Parameters
List of parameters
1-494
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Setting parameter for the run sequence of instance PCL 1 within the run-time group set in p20156.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for the input pulse I of instance PDE 0 of the closing delay device.
Description: Setting parameter for pulse delay time T in milliseconds of instance PDE 0 of the closing delay device.
Description: Display parameter for output pulse Q of instance PDE 0 of the closing delay device.
Description: Setting parameter for the run-time group in which instance PDE 0 of the closing delay device is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
p20157 PCL 1 run sequence / PCL 1 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
0 32000 410
p20158 BI: PDE 0 input pulse I / PDE 0 inp_pulse I
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7232
Min Max Factory setting
- - 0
p20159 PDE 0 pulse delay time in ms / PDE 0 t_del ms
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7232
Min Max Factory setting
0.00 5400000.00 0.00
r20160 BO: PDE 0 output Q / PDE 0 output Q
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7232
Min Max Factory setting
- - -
p20161 PDE 0 run-time group / PDE 0 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7232
Min Max Factory setting
5 9999 9999