Siemens SINAMICS G120D - p9484 BICO interconnections search signal source; BICO S_src srch; r9485 BICO interconnections signal source search count; BICO S_src srchQty; r9486 BICO interconnections signal source search first index; BICO S_src srchIdx; p9501 SI Motion enable safety functions (Control Unit); SI Mtn enable CU

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-415
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency: Refer to: r9485, r9486
Description: Displays the number of BICO interconnections to the signal sink being searched for.
Dependency: Refer to: p9484, r9486
Note: The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
Description: Displays the first index of the signal source being searched for.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency: Refer to: p9484, r9485
Note: The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
Description: Sets the enable signals for the safe motion monitoring.
Dependency: Refer to: F01682, F01683
p9484 BICO interconnections search signal source / BICO S_src srch
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 4294967295 0
r9485 BICO interconnections signal source search count / BICO S_src srchQty
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r9486 BICO interconnections signal source search first index / BICO S_src srchIdx
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
p9501 SI Motion enable safety functions (Control Unit) / SI Mtn enable CU
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 0000 0000 0000 0000 0000
0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Enable SI Motion Enable Inhibit -
16 Enable SSM (n < nx) hysteresis and filtering Enable Inhibit 2823
17 Enable SDI Enable Inhibit 2824
30 Enable F-DI in PROFIsafe telegram Enable Inhibit -