Description: Runs the corresponding macro files.
Notice: After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
When executing a specific macro, the corresponding programmed settings are made and become active.
Note: Macros available as standard are described in the technical documentation of the particular product.
The parameter is not influenced by setting the factory setting.
Description: Displays the firmware version of the Control Unit.
Dependency: Refer to: r0197, r0198
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the currently smoothed speed setpoint at the input of the speed controller or U/f characteristic (after the
interpolator).
Dependency: Refer to: r0060
Note: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed setpoint is available smoothed (r0020) and unsmoothed (r0060).
Description: Displays the smoothed actual value of the motor speed.
For U/f control and when slip compensation is deactivated (see p1335), the synchronous speed to the output fre-
quency is shown in r0021.
Dependency: Refer to: r0022, r0063
p0015 Macro drive unit / Macro drv unit
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Unsigned32
Can be changed: C, C(1) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 999999 26
r0018 Control Unit firmware version / CU FW version
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 4294967295 -
r0020 Speed setpoint smoothed / n_set smth
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Units group: 3_1 Unit selection: p0505 Func. diagram: 5020, 6799
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
r0021 CO: Actual speed smoothed / n_act smooth
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Units group: 3_1 Unit selection: p0505 Func. diagram: 6799
Min Max Factory setting
- [rpm] - [rpm] - [rpm]