Siemens SINAMICS G120D - r20272 BO: LVM 0 input quantity below interval QL; LVM 0 X below QL; p20273 LVM 0 run-time group; LVM 0 RTG; p20274 LVM 0 run sequence; LVM 0 RunSeq; p20275 CI: LVM 1 input X; LVM 1 input X

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-518
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Display parameter of instance LVM 0 of the double-sided limiter that input quantity X was at least once X < M - L
and X is <= M - L + HY.
Description: Setting parameter for the run-time group in which instance LVM 0 of the double-sided limiter is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance LVM 0 within the run-time group set in p20273.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X of instance LVM 1 of the double-sided limiter.
Description: Setting parameter for the interval average M of instance LVM 1 of the double-sided limiter.
r20272 BO: LVM 0 input quantity below interval QL / LVM 0 X below QL
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
- - -
p20273 LVM 0 run-time group / LVM 0 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
5 9999 9999
p20274 LVM 0 run sequence / LVM 0 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
0 7999 720
p20275 CI: LVM 1 input X / LVM 1 input X
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
- - 0
p20276 LVM 1 interval average value M / LVM 1 avg value M
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000