Siemens SINAMICS G120D - r9723.0...16 CO;BO: SI Motion diagnostic signals integrated in the drive; SI Mtn integ diag; r9724 SI Motion crosswise comparison clock cycle; SI Mtn CDC clk cyc

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-433
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Notice: Re bit 07:
An internal event is displayed if a STOP A ... F is active.
The signal state behaves in an opposite way to the PROFIsafe Standard.
Note: This parameter is only supplied with actual values if SI Motion functions are active. For Safety Integrated Basic
Functions (STO), the value is equal to zero.
Description: Displays the diagnostic signals for safety-relevant motion monitoring functions integrated in the drive.
Note: Re bit 01:
This bit can be used to execute a control-based ESR.
ESR: Extended Stop and Retract
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
Description: Displays the crosswise comparison clock cycle.
The value indicates the clock cycle time with which each individual CDC value is compared between the two moni-
toring channels.
Note: CDC: Crosswise Data Comparison
12 SDI pos active Yes No 2824
13 SDI neg active Yes No 2824
15 SSM (speed below limit value) Yes No 2823
r9723.0...16 CO/BO: SI Motion diagnostic signals integrated in the drive / SI Mtn integ diag
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Forced checking procedure required Yes No -
01 STOP F and then STOP B active Yes No -
02 Communication failure Yes No -
03 Actual value sensing supplies valid value Yes No -
04 Encoderless act val sensing acc to tech-
nique for U/f control
Yes No -
09 Safe pulse cancellation active Yes No -
12 Test stop active Yes No -
16 SAM/SBR active Yes No -
r9724 SI Motion crosswise comparison clock cycle / SI Mtn CDC clk cyc
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [ms] - [ms] - [ms]