Encoder evaluation
Function diagrams
2-691
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Fig. 2-100 4730 – Encoder interface, send signals, encoders 1 ... 2
- 4730 -
Function diagram
87654321
fp_4730_97_55.vsd
Encoder evaluation
SINAMICS G120D
12.12.2012 V4.6
Encoder interface, send signals, encoders 1 ... 2
Reserved
Index [n-1] --> encoder n
Index [0] --> encoder 1
Index [1] --> encoder 2
r0481[n-1]
Geb Gn_ZSW
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 0
Bit
Bit 12
Bit 13
Bit 14
Bit 15
4
3
2
1
PROFIdrive-Bit
Function
no.
Encoder status bits from
the position sensing,
encoder n
[4704.8]
Status word from encoder n (n = 1 or 2)
Feedback signal of the active function (1 = function active)
For reference number and flying measurement
reference mark 1 or measuring probe 1
reference mark 2 or measuring probe 1
reference mark 3 or measuring probe 2
reference mark 4 or measuring probe 2
1 = Position actual value from function 1
1 = Position actual value from function 2
1 = Position actual value from function 3
1 = Position actual value from function 4
1 = Measuring probe 1 deflected (high signal)
1 = Measuring probe 2 deflected (high signal)
1 = Acknowledge encoder fault active
Reserved (for reference point offset)
Absolute value is cyclically transferred
Parking encoder active (i.e. the encoder is not operational)
Encoder fault, the fault is in Gn_XIST2 (r0483)
Generated
value
in Gn_XIST2
(and can be
read)
Position value 2 from encoder n
The contents of position actual value 2 (Gn_XIST2) at [4704] depends on Gn_STW and Gn_ZSW.
This can be done as follows:
- Undefined for a parking encoder (Gn_ZSW.14 = 1).
- For Gn_ZSW.15 = 1 the fault code for encoder faults is located here.
- Position actual value at the reference mark (for Gn_STW.7 = 0 and Gn_ZSW.4-7 > 0; with handshake).
- Position actual value due to flying measurement (for Gn_STW.7 = 1 and Gn_ZSW.4.7 > 0; with handshake).
- Cyclic absolute position value (free-running value, e.g. from the SSI absolute track (for Gn_ZSW.13 = 1).
From the measuring probe
evaluation
[4740.4]
to the sequence control for Gn_XIST2
[4704.5]