Siemens SINAMICS G120D - r1776[0...6] Motor model status signals; MotMod status sig; r1778 Motor model flux angle difference; MotMod ang. diff.; p1780[0...n] Motor model adaptation configuration; MotMod adapt conf

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-230
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the internal status signals of the motor model:
Index 0: Changeover ramp between current and voltage models
Index 1: Changeover ramp for model tracking (encoderless induction motors only)
Index 2: Changeover ramp for zero frequency range (encoderless induction motors only)
Index 3: Transition ramp actual speed from speed setpoint to model value (encoderless FEM)
Index 4: Speed controller enable (encoderless FEM)
Index 5: Transition ramp between current and voltage models (encoderless FEM)
Index 6: Transition ramp for EMF deviation at PLL input (encoderless PESM)
Index: [0] = Changeover ramp motor model
[1] = Changeover ramp model tracking
[2] = Changeover ramp zero frequency encoderless ASM
[3] = Changeover ramp actual speed encoderless FEM
[4] = Enable speed controller encoderless FEM
[5] = Changeover ramp motor model encoderless FEM
[6] = Changeover ramp motor model encoderless PESM
Note: Indices 3 through 5 are only relevant in the case of encoderless control of separately excited synchronous motors.
Description: Displays the difference between the motor model flux angle and the transformation angle.
Dependency: A setting for smoothing the display can be made using p1754.
Description: Sets the configuration for the adaptation circuit of the motor model.
Induction motor (ASM): Rs, Lh, and offset compensation.
Permanent magnet synchronous motor (PEM): kT
r1776[0...6] Motor model status signals / MotMod status sig
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r1778 Motor model flux angle difference / MotMod ang. diff.
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2005 Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [°] - [°] - [°]
p1780[0...n] Motor model adaptation configuration / MotMod adapt conf
Access level: 4 Calculated: p0340 = 1,3,4 Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 0000 0111 1100 bin
Bit field: Bit Signal name 1 signal 0 signal FP
01 Select motor model ASM Rs adaptation Yes No -
02 Select motor model ASM Lh adaptation Yes No -
03 Select motor model PEM kT adaptation Yes No -
04 Select motor model offset adaptation Yes No -
05 Select ASM Rr adaptation (only with
encoder)
Yes No -
06 Select pole position identification PEM
encoderless
Yes No -
07 Select T(valve) with Rs adaptation Yes No -
10 Filter time combination current like current
ctrl integral time
Yes No -