EasyManua.ls Logo

Siemens SINAMICS G120D - p20054[0...3] BI: OR 2 inputs; OR 2 inputs; r20055 BO: OR 2 output Q; OR 2 output Q; p20056 OR 2 run-time group; OR 2 RTG; p20057 OR 2 run sequence; OR 2 RunSeq

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-470
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the signal source of input quantities I0, I1, I2, I3 of instance OR 2 of the OR function block.
Index: [0] = Input I0
[1] = Input I1
[2] = Input I2
[3] = Input I3
Description: Display parameter for binary quantity Q = I0 | I1 | I2 | I3 of instance OR 2 of the OR function block.
Description: Setting parameter for the run-time group in which the instance OR 2 of the OR function block is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance OR 2 within the run-time group set in p20056.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20054[0...3] BI: OR 2 inputs / OR 2 inputs
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7212
Min Max Factory setting
- - 0
r20055 BO: OR 2 output Q / OR 2 output Q
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7212
Min Max Factory setting
- - -
p20056 OR 2 run-time group / OR 2 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7212
Min Max Factory setting
1 9999 9999
p20057 OR 2 run sequence / OR 2 RunSeq
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7212
Min Max Factory setting
0 32000 80

Table of Contents

Other manuals for Siemens SINAMICS G120D

Related product manuals